LOINC

LOINC (Logical Observation Identifiers Names and Codes) gives a universal identifier to the question being asked in a laboratory test, a clinical measurement or a standardized questionnaire.

Local laboratory codes are meaningless outside the laboratory that assigned them. HGB, HB, HEMO and 001234 might all mean haemoglobin in blood — and only LOINC lets a receiving system know that.


The six axes​

Every LOINC code is defined by six parts, which is what makes it precise:

AxisQuestionExample
ComponentWhat is measured?Hemoglobin
PropertyWhat kind of quantity?MCnc (mass concentration)
TimePoint in time or interval?Pt
SystemWhat specimen or body site?Bld (blood)
ScaleQuantitative, ordinal, nominal, narrative?Qn
MethodHow, if it matters?(often unspecified)

718-7 = Hemoglobin : MCnc : Pt : Bld : Qn

Codes are numeric with a check digit; they carry no meaning in themselves, which is deliberate.


What LOINC covers​

  • Laboratory tests — chemistry, haematology, microbiology, serology
  • Clinical measurements — vital signs, anthropometry, scores
  • Survey instruments — standardized assessment questions and answers
  • Document types — the kind of clinical note or report

LOINC identifies the observation; the result is carried separately, with units (UCUM) and, where the result is itself coded, a terminology such as SNOMED CT.


LOINC in FHIR​

{
"resourceType": "Observation",
"status": "final",
"code": {
"coding": [{
"system": "http://loinc.org",
"code": "718-7",
"display": "Hemoglobin [Mass/volume] in Blood"
}]
},
"valueQuantity": {
"value": 11.2,
"unit": "g/dL",
"system": "http://unitsofmeasure.org",
"code": "g/dL"
}
}

LOINC is the expected code system for Observation.code in most FHIR implementation guides, and it appears in OBX-3 of HL7 v2 result messages.


Mapping a laboratory catalogue​

  1. Export the local test catalogue with names, specimens, units and methods.
  2. Map the highest-volume tests first — a small number of tests usually cover most of the traffic.
  3. Use RELMA or the LOINC search tools; match on all six axes, not on the name.
  4. Have a laboratory professional review the mappings; specimen and property mistakes are easy to make and hard to detect later.
  5. Version the mapping table and treat it as maintained metadata, not a one-time migration artefact.

Common mistakes​

  • Mapping on component alone. Glucose in serum and glucose in urine are different codes.
  • Ignoring property. Mass concentration and substance concentration are not interchangeable, and neither are their units.
  • Mapping panels to member codes. Panels have their own codes.
  • Skipping units. A LOINC code without UCUM units is only half an answer.

References​